Skip to main content Site map

Architect's Handbook of Construction Detailing 2nd edition


Architect's Handbook of Construction Detailing 2nd edition

Hardback by Ballast, David Kent

Architect's Handbook of Construction Detailing

WAS £87.95   SAVE £13.19

£74.76

ISBN:
9780470381915
Publication Date:
28 Jul 2009
Edition/language:
2nd edition / English
Publisher:
John Wiley & Sons Inc
Pages:
480 pages
Format:
Hardback
For delivery:
Estimated despatch 2 - 4 May 2024
Architect's Handbook of Construction Detailing

Description

Significantly updated with revisions to nearly all 200-plus details, this second edition of Architect's Handbook of Construction Detailing provides architects, engineers, interior designers, contractors, and other building professionals with all of the common construction details, materials information, and detailing concepts used throughout the industry. The information can be used as is or modified to fit individual project designs. Each of book's seven sections -- formatted to follow the new six-digit CSI MasterFormat system -- contains details and related information, including descriptions, detailing considerations, material requirements, installation requirements, tolerance coordination, and likely failure points. Additionally, SI (metric) equivalents have been added to all dimensions.

Contents

List of Tables xi Preface xiii Acknowledgments xv Introduction xvii How SI Units Are Used in this Book xix Abbreviations xxi 1 Concrete Details 1 1-1 Concrete Slab-on-Grade Tolerances 03 05 03 1 1-2 Cast-in-Place Concrete Sectional Tolerances 03 05 04 4 1-3 Cast-in-Place Concrete Plan Tolerances 03 05 05 5 1-4 Waterstops 03 15 13 7 1-5 Slab-on-Grade Control Joint 03 30 07 9 1-6 Slab-on-Grade Isolation Joint 03 30 08 12 1-7 Slab-on-Grade Construction Joint 03 30 09 14 1-8 Cast-in-Place Concrete Wall with Insulation 03 30 53 16 1-9 Architectural Concrete 03 30 00 19 1-10 Precast Concrete Spandrel with Insulation 03 40 01 22 1-11 Precast Concrete Beam and Double Tee Tolerances 04 41 00 25 1-12 Autoclaved Aerated Concrete Panels 04 22 23.1 27 1-13 Architectural Precast Concrete Panel Tolerances 03 45 13 30 1-14 Architectural Precast Panel Size and Configuration 03 45 14 32 1-15 Architectural Precast Concrete Forming 03 45 15 34 1-16 Architectural Precast Corners 03 45 16 36 1-17 Architectural Precast Joints 03 45 17 39 1-18 Architectural Precast Weathering Details 03 45 18 40 1-19 Architectural Precast Panel Connections 03 45 19 42 1-20 Architectural Precast Spandrel Panels 03 45 20 44 1-21 Architectural Precast Parapet 03 45 21 45 1-22 Cast-in-Place/Precast Connection 03 45 90 47 1-23 Precast Floor/Beam Erection Tolerances 03 45 91 49 1-24 Glass Fiber Reinforced Concrete Panels 03 49 00 51 2 Masonry Details 55 2-1 Vertical Concrete Masonry Expansion Joint 04 05 23.1 55 2-2 Vertical Brick Expansion Joint 04 05 23.2 58 2-3 Vertical Masonry Expansion Joint in Composite Wall 04 05 23.3 62 2-4 Brick/Masonry Cavity Wall at Grade 04 21 10.1 65 2-5 Brick/Masonry Cavity Wall at Spandrel 04 21 10.2 69 2-6 Brick/Masonry Cavity Wall at Roof/Parapet 04 21 10.3 71 2-7 Masonry Grouted Wall 04 21 10.4 74 2-8 Brick Veneer, Wood Studs 04 21 13.1 78 2-9 Brick Veneer, Steel Stud Backing Wall 04 21 13.2 82 2-10 Brick Veneer, Steel Stud Backup Wall at Opening 04 21 13.3 87 2-11 Brick on Shelf Angle 04 21 13.4 91 2-12 Shelf Angle on Steel Framing 04 21 13.5 96 2-13 Interior Masonry Bearing Partition 04 22 01 99 2-14 Wood Joists on Interior Masonry Bearing Partition 04 22 02 101 2-15 Autoclaved Aerated Concrete Masonry 04 22 26 102 2-16 Reinforced Concrete Masonry Wall at Grade 04 22 23.1 104 2-17 Reinforced Concrete Masonry Wall at Floor 04 22 23.2 107 2-18 Reinforced Concrete Masonry Wall at Parapet 04 22 23.3 109 2-19 Glass Block Wall at Sill and Head 04 23 13.1 110 2-20 Glass Block Wall at Jamb and Vertical Joint 04 23 13.2 113 2-21 Glass Block Wall-Alternate Details 04 23 13.4 115 2-22 Anchored Stone Veneer with Concrete Masonry Unit Backup at Grade 04 42 13.1 116 2-23 Anchored Stone Veneer with Concrete Masonry Unit Backup at Spandrel 04 42 13.2 120 2-24 Anchored Stone Veneer with Concrete Masonry Unit Backup at Parapet 04 42 13.3 122 2-25 Exterior Stone Veneer at Base 04 42 13.4 125 2-26 Exterior Stone Veneer at Spandrel 04 42 13.5 129 2-27 Exterior Stone Veneer at Parapet 04 42 13.6 130 2-28 Cut Stone on Concrete Backup Wall 04 42 13.7 132 2-29 Interior Stone Veneer 134 2-30 Interior Stone Veneer at Vertical Joint 04 42 16.2 135 2-31 Exterior Stone on Steel Truss Frame 04 42 23 136 2-32 Exterior Stone on Framing System 04 42 26 139 3 Metal Details 143 3-1 Structural Steel Column Erection Tolerances 05 05 03 143 3-2 Steel Column/Beam Connection Tolerances 05 05 03.1 145 3-3 Structural Steel Column Plan Tolerances 05 05 04 146 3-4 Structural Steel Column Location Tolerances 05 05 04.1 148 3-5 Structural Steel Support for Masonry 05 12 23.1 150 3-6 Structural Steel Support for Precast Concrete 05 12 23.3 152 3-7 Steel/Precast with Insulation 05 12 23.3 153 3-8 Structural Steel Support for Curtain Walls 05 12 23.5 155 3-9 Open Web Steel Joists 05 21 19 157 3-10 Stair Layout 05 51 00.1 158 3-11 Stair Layout at Base 05 51 00.2 160 3-12 Stair Layout at Landing 05 51 00.3 161 3-13 Stair Layout at Top Landing 05 51 00.4 162 3-14 Metal Stairs 05 51 13 164 3-15 Ornamental Metal/Glass Guard 05 52 13 165 3-16 Expansion Joint at Floor and Wall 05 54 00.1 166 4 Wood Details 169 4-1 Platform Framing at Foundation 06 11 00.1 169 4-2 Platform Framing at Stepped Foundation 06 11 00.2 172 4-3 Platform Framing at Roof 06 11 00.3 173 4-4 Multistory Framing at Foundation 06 11 00.4 175 4-5 Multistory Framing at Floor Line 06 11 00.5 177 4-6 Multistory Framing at Roof 06 11 00.6 178 4-7 Structural Insulated Panel at Foundation 06 12 00.1 179 4-8 Structural Insulated Panel at Roof 06 12 00.2 182 4-9 Glulam Beam at Foundation Wall 06 18 13.1 183 4-10 Glulam Beam at Column 06 18 13.2 185 4-11 Glulam Purlins at Beam 06 18 13.3 186 4-12 Glulam Roof Beam 06 18 13.4 188 4-13 Glulam Column at Base 06 18 16 190 4-14 Base Cabinet 06 41 00.1 191 4-15 Upper Cabinet 06 41 00.2 193 4-16 Countertops 06 41 00.3 195 4-17 Shelving 06 41 00.4 197 4-18 Flush Wood Paneling 06 42 16 199 5 Thermal and Moisture Protection Details 203 5-1 Foundation Waterproofing 07 13 00 203 5-2 Cold, Liquid-Applied Membrane Deck Waterproofing 07 14 00.1 206 5-3 Vegetated Protected Membrane Roofing 07 55 63 209 5-4 Slab-on-Grade Foundation Insulation 07 21 13 212 5-5 Weather Barrier Concepts 213 5-6 Exterior Insulation and Finish System at Base 224 5-7 Exterior Insulation and Finish System at Parapet 229 5-8 Exterior Insulation and Finish System Openings 231 5-9 Asphalt/Glass Fiber Shingles at Eaves 07 31 13 232 5-10 Wood Shingles at Eaves 07 31 29 235 5-11 Roofing Tiles at Eaves 07 32 00 237 5-12 Preformed Metal Wall Panel at Base 07 42 13.1 238 5-13 Preformed Metal Wall Panel at Parapet 07 42 13.2 240 5-14 Roofing Systems on Steel Deck 07 22 00.1 241 5-15 Roofing Systems on Concrete Deck 245 5-16 Built-up Roof at Supported Deck 07 51 00.1 247 5-17 Built-up Roof at Nonsupported Deck 07 51 00.2 251 5-18 Built-up Roofing at Expansion Joint 07 51 00.3 252 5-19 Built-up Roof at Equipment Support 07 51 00.4 254 5-20 Built-up Roof at Stack Flashing 07 51 00.5 255 5-21 Modified Bitumen Roof at Supported Deck 07 52 00.1 256 5-22 Modified Bitumen Roof at Nonsupported Deck 07 52 00.2 260 5-23 Modified Bitumen Roof at Expansion Joint 07 52 00.3 261 5-24 Modified Bitumen Roof at Equipment Support 07 52 00.4 263 5-25 Modified Bitumen Roof at Plumbing Vent 07 52 00.5 264 5-26 EPDM Roof at Supported Deck 07 53 23.1 265 5-27 EPDM Roof at Nonsupported Deck 07 53 23.2 269 5-28 EPDM Roof at Expansion Joint 07 53 23.3 270 5-29 EPDM Roof at Equipment Support 07 53 23.4 272 5-30 EPDM Roof at Pipe Flashing 07 53 23.5 273 5-31 TPO Roof at Supported Deck 07 54 23.1 274 5-32 TPO Roof at Curb Threshold 07 54 23.2 277 5-33 TPO Roof at Expansion Joint 07 54 23.3 279 5-34 TPO Roof at Equipment Support 07 54 23.4 280 5-35 TPO Roof at Pipe Flashing 07 54 23.5 282 5-36 Protected Membrane Roofing 07 55 00 283 5-37 Gravel Stop 07 71 19 284 5-38 Vertical and Horizontal Joint Fillers and Sealants 07 92 00 286 5-39 Roof Drain 22 14 26.13 294 6 Door and Window Details 297 6-1 Steel Door and Frame Jamb, Masonry Wall 08 11 13.1 297 6-2 Steel Door and Head Frame, Masonry Wall 08 11 13.2 300 6-3 Steel Door and Frame, Gypsum Wallboard Wall 08 11 13.3 302 6-4 Aluminum Door Frame Assembly 08 11 16 305 6-5 Wood Door and Frame Assembly 08 14 00 306 6-6 Aluminum Storefront at Sill and Head 08 41 13.1 309 6-7 Aluminum Storefront at Mullion and Jamb 08 41 13.2 311 6-8 All-Glass Entrance Door 08 42 26.1 312 6-9 All-Glass Glazing System 08 42 26.2 314 6-10 All-Glass Glazing System at Mullion and Jamb 08 42 26.3 315 6-11 Aluminum Curtain Wall at Spandrel 08 44 13.1 316 6-12 Aluminum Curtain Wall at Roof 08 44 13.1 320 6-13 Aluminum Curtain Wall at Mullion 08 44 13.2 322 6-14 Four-sided Structural Silicone Glazing at Spandrel 08 44 26.1 324 6-15 Four-sided Structural Silicone Glazing at Mullion 08 44 26.2 328 6-16 Aluminum Window, Masonry Wall 08 51 13.3 329 6-17 Steel Window, Masonry Wall 08 51 23 331 6-18 Wood Window, Masonry Wall 08 52 00.3 333 6-19 Wood Window, Wood Frame Wall 08 52 00.4 335 6-20 Interior, Framed Glazed Opening at Jamb 08 81 00.1 336 6-21 Interior, Framed Glazed Opening at Sill and Head 08 81 00.2 338 6-22 Interior Frameless Glazed Opening at Jamb 08 81 00.3 339 6-23 Interior Frameless Glazed Opening at Sill and Head 08 81 00.4 341 6-24 Interior Fire-Resistant Rated Glazing 08 88 60 342 7 Finish Details 347 7-1 Gypsum Wallboard Shaft Lining 09 21 16 347 7-2 Gypsum Wallboard, Nonrated Partition 09 29 03.1 350 7-3 Gypsum Wallboard, Slip Joint at Structural Slab 09 29 03.2 353 7-4 Gypsum Wallboard, Proprietary Slip Joint 09 29 03.3 356 7-5 One-Hour Gypsum Wallboard Partition, Wood Framing 09 29 03.4 357 7-6 Sound-Rated One-Hour Gypsum Wallboard Partition 09 29 03.5 359 7-7 One-Hour Gypsum Wallboard Partition, Metal Framing 09 29 03.6 361 7-8 Two-Hour Gypsum Wallboard Partition, Wood Framing 09 29 05.1 363 7-9 Two-Hour Gypsum Wallboard Partition, Metal Framing 09 29 05.2 365 7-10 Three-Hour Gypsum Wallboard Partition 09 29 07.1 367 7-11 Three-Hour Fire-Rated Column Cover 09 29 07.2 369 7-12 Perimeter Relief Joint 09 29 09 370 7-13 One-Hour Gypsum Wallboard Ceiling, Wood Framing 09 29 11.1 372 7-14 Two-Hour Suspended Gypsum Wallboard Ceiling 09 29 11.2 373 7-15 Ceramic Tile Floor, Thin-Set on Wood Framing 09 31 13.1 375 7-16 Ceramic Tile Wall, Thin-Set 09 31 13.2 378 7-17 Movement Joint with Thin-Set Tile 09 31 13.3 380 7-18 Ceramic Tile Floor, Thick-Set on Membrane Over Concrete 09 32 13.1 382 7-19 Ceramic Tile Floor, Full Mortar Bed 09 32 13.2 385 7-20 Ceramic Tile Ceiling 09 32 13.3 387 7-21 Ceramic Tile Wall, Full Mortar Bed 09 32 13.4 388 7-22 Ceramic Tile Expansion Joint 09 32 13.5 390 7-23 One-Hour Acoustical Ceiling Assembly 09 50 13.1 392 7-24 Two-Hour Acoustical Ceiling Assembly 09 50 13.2 394 7-25 Stone Flooring, Thin-Set 09 63 40.1 396 7-26 Stone Flooring, Full Mortar Bed 09 63 40.2 397 7-27 Wood Parquet Flooring 09 64 23 399 7-28 Wood Strip Flooring on Wood Framing 09 64 29.1 401 7-29 Wood Strip Flooring on Concrete Framing 09 64 29.2 402 7-30 Laminate Flooring 09 62 19 404 7-31 Resilient Wood Flooring System 09 64 53 405 7-32 Portland Cement Terrazzo, Sand Cushion 09 66 13.13 407 7-33 Portland Cement Terrazzo, Monolithic 09 66 13.16 409 7-34 Portland Cement Terrazzo, Bonded 09 66 13.19 411 Appendix A: Standards Titles 415 Appendix B: Sources for More Information 423 CSI Six-Digit Number Index 431 Index 437

Back

JS Group logo